E3X-HD11

Liên hệ

In Stock

Sku: C00039

Surprisingly Stable Detection with Your Finger tip. Exceptionally easy operation and stabilizing technology reduce maintenance cost.

Xem list sp yêu thích
So sánh
Type Standard Model for
Sensor Communications
Unit *1
NPN output E3X-HD11 E3X-HD6 E3X-HD14 E3X-HD0
PNP output E3X-HD41 E3X-HD8 E3X-HD44
Connecting method Pre-wired Wire-saving
Connector
*2
M8
connector
Communications
Unit connector
Light source (wavelength) Red, 4-element LED (625 nm)
Power supply voltage 12 to 24 VDC ±10%, ripple (P-P) 10% max. Supplied from the connector
through the Sensor
Communications Unit
Power
consump
tion
Normal mode 720 mW max.
(Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)
Eco ON 530 mW max.
(Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC)
Eco LO 640 mW max. (Current consumption: 26 mA max. at
24 VDC, 53 mA max.at 12 VDC)
Control output Load power supply voltage: 26.4 VDC max., open-
collector output
Load current:
Groups of 1 to 3 Amplifier Units: 100mA max.,
Groups of 4 to 16 Amplifier Units: 20mA max.
Residual voltage:
At load current of less than 10 mA: 1 V max.,
At load current of 10 to 100 mA: 2 V max.
OFF current: 0.1 mA max.
Protection circuits Power supply reverse polarity protection, output
short-circuit protection and output reverse
polarity protection
Power supply reverse polarity
protection and output short-
circuit protection
Response
time
Super-high-speed
mode (SHS) *3
NPN outputs: Operate or reset: 50 μs
PNP outputs: Operate or reset: 55 μs
High-speed Mode
(HS)
Operate or reset: 250 μs (default setting)
Standard Mode
(STND)
Operate or reset: 1 ms
Giga-power Mode
(GIGA)
Operate or reset: 16 ms
Maximum connectable Units 16 units with E3X-CRT: 16 units
with E3X-ECT: 30 units
Mutual interference
prevention
Possible for up to 10 units (optical communications sync) *3
Auto power control (APC) Always ON
Other functions Power tuning, differential detection, DPC, timer (OFF-delay, ON-delay, or one-shot),
zero reset, resetting settings, and Eco mode
Ambient illumination
(Receiver side)
Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Ambient temperature range OOperating:
Groups of 1 to 2 Amplifiers: -25 to 55°C,
Groups of 3 to 10 Amplifiers: -25 to 50°C,
Groups of 11 to 16 Amplifiers: -25 to 45°C
Storage: -30 to 70°C
(with no icing or condensation)
Operating:
Groups of 1 to 2 Amplifiers:
0 to 55°C,
Groups of 3 to 10 Amplifiers:
0 to 50°C,
Groups of 11 to 16 Amplifiers:
0 to 45°C,
Groups of 17 to 30 Amplifiers:
0 to 40°C
Storage: -30 to 70°C
(with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
(destruction)
10 to 55 Hz with a 1.5-mm double amplitude for
2 hours each in X, Y, and Z directions
10 to 150 Hz with a 0.7-mm
double amplitude for 80 minutes
each in X, Y, and Z directions
Shock resistance
(destruction)
500 m/s2 for 3 times each in X, Y, and Z
directions
150 m/s2 for 3 times each in
X, Y, and Z directions
Degree of protection IEC 60529 IP50
(with Protective Cover attached)
Weight
(packed state/unit only)
Approx. 105 g/
Approx. 65 g
Approx. 60 g/
Approx. 20 g
Approx. 70 g/
Approx. 25 g
Approx. 65 g/Approx. 25 g
Materials Case Polycarbonate (PC) Heat-resistant ABS
(connector: PBT)
Cover Polycarbonate (PC)
Cable PVC
Accessories Instruction Manual